<LOGO>
FM Transmitter Measurement Report
Created: 2026-11-03 21-40-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 49 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 2.8 kHz -42 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 42 kHz 15676 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,1 dBr 1,50 dBr 2,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sonaatti D-Duuri: II. Andante Sostenuto (Schubert) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 42 kHz MIN: 15 kHz % above 76 kHz: 0,0000 Acquired: 2026.11.03 21.39.26 Total samples: 15676 Equivalent time: 0:13:03 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 2,7 dBr MIN: -0,1 dBr AVE: 1,50 dBr % above 12,2 dBr: 0,0 Last value: 2,4 dBr (2026.11.03 21.39.26) 21.26 21.28 21.30 21.32 21.34 21.36 21.38 -1 0 1 2 3 Pm [dBr]